Husky 1050 Plastic Pump |
Maximum fluid working pressure |
125 psi ( 8.6 bar ) |
Air pressure operating range |
20 ~ 125 psi (1.4 ~ 8.6 bar ) |
Fluid displacement per cycle |
0.17 gal. ( 0.64 liters ) |
Air consumption at 70 psi ( 0.48 MPa, 4.8 bar ), 20 gpm ( 76 lpm ) |
25 scfm |
Maximum values with water as media under submerged inlet conditions at ambient temperature ( Maximum air consumption ) |
67 scfm |
Maximum values with water as media under submerged inlet conditions at ambient temperature ( Maximum free flow delivery ) |
50 gpm ( 189 lpm ) |
Maximum values with water as media under submerged inlet conditions at ambient temperature ( Maximum pump speed ) |
280 cpm |
Maximum values with water as media under submerged inlet conditions at ambient temperature ( Maximum suction lift ) |
Dry: 16 ft ( 4.9 m )
Wet: 29 ft ( 8.8 m ) |
Maximum size pumpable solids |
1/8” ( 3.2 mm ) |
Recommended cycle rate for continuous use |
93 ~ 140 cpm |
Recommended cycle rate for circulation system |
20 cpm |
Fluid temperature range |
|
Air inlet size |
1/2 npt (f) |
Fluid inlet size ( Conductive poly 1050C, polypropylene 1050P, or PVDF 1050F ) |
1” raised face ANSI / DIN Flange |
Fluid outlet size ( Conductive poly 1050C, polypropylene 1050P, or PVDF 1050F ) |
1” raised face ANSI / DIN Flange |
Weight |
Conductive polypropylene 1050C, Polypropylene 1050P: 18 lb ( 8.2 kg )
PVDF ( 1050F ): 26 lb ( 11.8 kg ) |
Size |
|
Wetted parts include materials chosen for seat, ball and diaphragm options, plus the pump’s material |
1050C and 1050P: Polypropylene
1050F: PVDF |
Non wetted external parts of construction |
Plastic ( 1050P, 1050C and 1050F ): stainless steel, polypropylene |